MeriCal, LLC
Does MeriCal, LLC have an FDA record?
Yes. MeriCal, LLC has no FDA warning letters and 3 supplement recalls (Oct 24, 2025, Jan 9, 2020 and Mar 19, 2019) in this index. It has 6 FDA inspections in this index: 2 classified VAI (Dec 19, 2024 and Nov 20, 2017) and 4 NAI (latest Aug 27, 2024).
- Name in FDA records
- MeriCal, LLC
- Location
- CA, United States
- FDA FEI numbers
- 2010498, 3001574462, 3011412977
- Warning letters
- 0
- Recalls
- 3
- Inspections
- 6 (0 OAI)
- Latest record
- Oct 24, 2025
FDA warning letters
No supplement warning letter to this name appears in the FDA letters this index covers (issued since Jan 6, 2021).
Recalls
| Product | Reason (as FDA reported it) | |||
|---|---|---|---|---|
| Oct 24, 2025 | Member's Mark Super Greens Dietary Supplement; 48 servings; Net Weight 18.28 oz (518.4g) UPC: 193968490775 | Potential contamination of Salmonella Richmond | I | Ongoing |
| Jan 9, 2020 | Meijer Joint Health Movement Advanced Dietary Supplement with Glucosamine + Chondroitin. 1500 mg; Supports Joint Mobility and Comfort; Unit Size - 80 count - 2 tablets per day. Item Numbers: MEIJER7383 UPC Code:... | Product label does not contain Crustacean Shellfish on the ingredient list or allergen information | II | Terminated |
| Mar 19, 2019 | Walgreens Probiotic 12.5 Billion Active Cultures, 30 capsules; Dietary Supplement. Probiotic Blend 12.5 Billion CFU's L. rhamnosus HN001, L acidophilus La-14, L reuteri L.RE02. Other ingredients: Cellulose,... | Incorrect probiotic strain used in formulation which did not match product labeling. | III | Terminated |
FDA inspections
The classification is FDA’s outcome for the inspection. Part 111 citations are Form 483 observations: investigator observations, not a final FDA determination.
| Sections cited on the Form 483 | FEI | ||||
|---|---|---|---|---|---|
| Dec 19, 2024 | Orange, CA | VAI | 8 | 111.155, 111.10, 111.70, 111.27, 111.113, 111.210, 111.260 | 3001574462 |
| Aug 27, 2024 | Anaheim, CA | NAI | 0 | 2010498 | |
| May 9, 2024 | Orange, CA | NAI | 0 | 3011412977 | |
| Nov 20, 2017 | Orange, CA | VAI | 2 | 111.210, 111.75 | 3001574462 |
| Jan 23, 2015 | Anaheim, CA | NAI | 0 | 2010498 | |
| Feb 27, 2013 | Orange, CA | NAI | 0 | 3001574462 |
Classifications: No Action Indicated (NAI), Voluntary Action Indicated (VAI), Official Action Indicated (OAI). Facility FEI 3001574462 is included because at least one FDA Form 483 from an inspection there cited 21 CFR Part 111, the dietary supplement manufacturing rule. Facilities FEI 2010498 and 3011412977 are included because its FDA legal name matches a firm in this index’s supplement warning letters or supplement recalls. Each row is an FDA Food/Cosmetics inspection of the facility; FDA’s inspection data does not say which products an inspection covered.
Part 111 observations on each Form 483
A Form 483 lists investigator observations, not a final FDA determination.
Dec 19, 2024, MeriCal LLC, Orange (inspection 1229480, Food Composition, Standards, Labeling and Econ: Voluntary Action Indicated (VAI); Foodborne Biological Hazards: No Action Indicated (NAI))
- 21 CFR 111.155(e): Components - contamination, deterioration, mix-ups (111.155: What requirements apply to components of dietary supplements?)
- 21 CFR 111.10(b): Hygienic practices (111.10: What requirements apply for preventing microbial contamination from sick or infected personnel and for hygienic practices?)
- 21 CFR 111.70(e): Specifications - finished dietary supplement (111.70: What specifications must you establish?)
- 21 CFR 111.27(a): Equipment - design - appropriate and suitable (111.27: What requirements apply to the equipment and utensils that you use?)
- 21 CFR 111.113(b)(2): Quality control - reject; specification not met (111.113: What quality control operations are required for a material review and disposition decision?)
- 21 CFR 111.70(b): Specifications - components (111.70: What specifications must you establish?)
- 21 CFR 111.210: Master manufacturing record - record requirements (111.210: What must the master manufacturing record include?)
- 21 CFR 111.260: Batch record - required information (111.260: What must the batch record include?)
Nov 20, 2017, MeriCal LLC, Orange (inspection 1031829, Food Composition, Standards, Labeling and Econ: Voluntary Action Indicated (VAI))
- 21 CFR 111.210(h)(2): Master manufacturing record - sampling, tests, examinations (111.210: What must the master manufacturing record include?)
- 21 CFR 111.75(c): Specifications met - verify; finished batch (111.75: What must you do to determine whether specifications are met?)
FDA adverse event reports (CAERS)
No CAERS report in FDA data from May 13, 1999 to Jun 30, 2026 names a product under this company’s name. That is not a finding that no reports exist about its products: reports filed under other brand names are not matched. Some product names in CAERS begin with the same words as this company’s name; they are not counted here because the names are not an exact match, and they may be another firm’s products.
A report is not proof the product caused the event. A CAERS report is an unverified report submitted to FDA by a consumer, health professional or company. It does not show that the product caused the reaction. Report counts reflect how often people report and how widely a product is sold, not how risky it is.
CAERS lists products by the name the reporter gave, usually a brand and product name, not the maker’s legal name. Reports about this company’s products sold under another brand name would not be matched. See all supplement adverse event reports.
Ingredients named in these records
This company’s recalls, warning letters, import records or Health Fraud Product Database entries name chondroitin, glucosamine and probiotics. Each ingredient page lists every FDA record in this index that names it. A record naming an ingredient may be about something else in the product.
This page lists public regulatory records as published by the issuing agency. A record is not a finding by this site. A warning letter states the agency’s view at the time it was issued; companies may have responded or corrected the issue since. Follow each link for the original document and any close-out letter. Report an error or add a company response.
Records are matched by company name across FDA sources. Firms with similar names can be different companies; check the FEI number and address on each original record.
Sources
- openFDA food enforcement reports
- FDA Data Dashboard: inspections, citations and published 483s
- openFDA food, dietary supplement and cosmetic adverse event reports (CAERS)
Records last pulled Nov 22, 2026. Every entry links to the original public record.